AC Size & Tonnage Calculator Burlington, ON
Proper sizing is the single most overlooked factor in AC performance.
Find the right tonnage for your Burlington home — not too big, not too small.
📐 Ontario Climate Data
⚡ Instant Result
🔒 Free
By submitting this form, you are giving your consent to receive phone calls and text messages from our contractor partners.
Get a Confirmed Size from a Pro
A certified HVAC contractor performs a Manual J load calculation for exact sizing.
Get Free QuotesWhat Size AC Does a Burlington Home Need?
| Home Size (sq ft) | Starting Estimate | BTU/h Range |
|---|---|---|
| 700 – 1,000 | 1.5 tonnes | 18,000 BTU/h |
| 1,000 – 1,400 | 1.5 – 2 tonnes | 18,000 – 24,000 BTU/h |
| 1,400 – 1,900 | 2 – 2.5 tonnes | 24,000 – 30,000 BTU/h |
| 1,900 – 2,500 | 2.5 – 3 tonnes | 30,000 – 36,000 BTU/h |
| 2,500 – 3,200 | 3 – 3.5 tonnes | 36,000 – 42,000 BTU/h |
| 3,200 – 4,200 | 3.5 – 5 tonnes | 42,000 – 60,000 BTU/h |
Why Oversizing Is a Real Problem in Burlington
Burlington vs. Other Ontario Cities — Sizing Impact
| City | Summer Design Temp (°C) | Sizing vs. Burlington |
|---|---|---|
| Windsor, ON | 33°C | +12% larger needed |
| London, ON | 32°C | +8% larger needed |
| Toronto, ON | 31°C | Similar to Burlington |
| Burlington, ON | 31°C | — Baseline — |
| Hamilton, ON | 31°C | Similar to Burlington |
| Ottawa, ON | 30°C | ~4% smaller possible |
Frequently Asked Questions
Not necessarily. If your homes face different directions, have different window sizes, or were insulated to different standards, their cooling load may differ meaningfully. That said, if your homes are nearly identical builds (same subdivision era, same floor plan, similar window configuration), their contractor's sizing is a useful data point — just not a substitute for a proper calculation for your specific home.
Manual J is the industry-standard heat load calculation method, developed by ACCA. A qualified HVAC technician uses your home's dimensions, insulation values, window specs, and local design temperatures to determine exact cooling load. You don't have to pay for it separately — reputable Burlington contractors typically perform a simplified Manual J calculation as part of their quoting process. Be cautious of any contractor who quotes a size without asking about your home's construction details.
Usually yes — if your current system has been comfortable and properly sized. But if your home was originally installed with an oversized unit (common in homes built in the 1990s), matching the old tonnage perpetuates the problem. If you've ever had the AC run constantly without reaching temperature in summer, undersizing is the issue. If it never runs long and the house feels humid, oversizing is likely the culprit.